Biometry Examination in Preparation for Cataract Surgery
DOI:
https://doi.org/10.21776/Keywords:
Cataract Surgery, BiometryAbstract
Cataract is the leading cause of blindness worldwide that actually preventable. Biometry is the process of measuring the corneal power and length of the eye. Inaccuracy in either of these measurements will lead to an unpredicted postoperative refractive error. Optimal biometry examination very important in determining the success of the cataract surgery in terms of the actual refractive outcome being congruent with the required refractive outcome.
References
Astari, P. Katarak: Klasifikasi, Tatalaksana, dan Komplikasi Operasi. Cermin Dunia Kedokteran. 2018; 45(10):748-753
World Health Organization. Blindness and vision impairment prevention, Priority Eye Diseases: Cataract. 2020. Available from: https://www.who.int/blindness/causes/priority/en/index1.html
Kementerian Kesehatan Republik Indonesia. Peta jalan penanggulangan gangguan pengelihatan di Indonesia 2017-2030. Jakarta, Direktorat Jenderal Pencegahan dan Pengendalian Penyakit Tidak Menular. 2018; 1-38
Ferreira TB, Hoffer KJ, Ribeiro F, Ribeiro P, O’Neill JG (2017) Ocular biometric measurements in cataract surgery candidates in Portugal. PLoS ONE 12(10): e0184837. https://doi. org/10.1371/journal.pone.0184837
Ademola-Popoola DS, Nzeh DA, Saka SE, Olokoba LB, Obajolowo TS. Comparison of ocular biometry measurements by applanation and immersion A-scan techniques. Journal of Current Ophthalmology. 2015 Sep-Dec;27(3-4):110-114. DOI: 10.1016/j.joco.2015.12.002.
National Institute for Health and Care Excellence (UK). Cataracts in adults: management. London: National Institute for Health and Care Excellence (UK); 2017 Oct. (NICE Guideline, No. 77.) 7, Preoperative assessment and biometry. Available from: https://www.ncbi.nlm.nih.gov/books/NBK536589/
Cantor LB, Rapuano CJ, McCannel CA. Lens and Cataract. Jick SL, Beardsley TL, Brasington CR, Buznego C, Grostern RJ, Park L, et al.,editor. Academy of Ophthalmology (2019-2020 edition)
Shahzad HSF. Biometry for Intra-Ocular Lens (IOL) power calculation. America Academy of Opthalmology. 2020. Available from: https://eyewiki.aao.org/Biometry_for_IntraOcular_Lens_(IOL)_power_calculation
Mohan P, Chakrabarti A. Intraocular lens power calculation in 2019: The cutting edge. Kerala J Ophthalmol 2019;31:191-201
Bartosz L. Sikorski, Pawel Suchon, "OCT Biometry (B-OCT): A New Method for Measuring Ocular Axial Dimensions", Journal of Ophthalmology, vol. 2019, Article ID 9192456, 10 pages, 2019. https://doi.org/10.1155/2019/9192456
Akman A, Asena L, Güngör SG. Evaluation and comparison of the new swept source OCT-based IOLMaster 700 with the IOLMaster 500. Br J Ophthalmol. 2016;100(9):1201-1205. doi:10.1136/bjophthalmol-2015-307779
Khan L, Sharma B, Gupta H, Rana R. Accuracy of biometry using automated and manual keratometry for intraocular lens power calculation. Taiwan J Ophthalmol. 2018;8(2):93-98. doi:10.4103/tjo.tjo_58_17
Kaushik K, Maitreya A, Raj A. Repeatability of manual and portable handheld automated keratometric measurements in pediatric population. J Clin Ophthalmol Res 2018;6:85-9
Nazm N, Chakrabarti A. Update on optical biometry and intraocular lens power calculation. TNOA J Ophthalmic Sci Res 2017;55:196-210.
Siddiqui AA, Devgan U. Intraocular lens calculations in atypical eyes. Indian J Ophthalmol. 2017;65(12):1289-1293. doi:10.4103/ijo.IJO_834_17
Steinert RF. Cataract surgery, 3rd edition, California, Saunders-Elsevier, 2010, 333-7
Xia, Tina MD; Martinez, Christine E. MD; Tsai, Linda M. MD Update on Intraocular Lens Formulas and Calculations, Asia-Pacific Journal of Ophthalmology: May-June 2020 - Volume 9 - Issue 3 - p 186-193
Wang L, Shirayama M, Ma XJ, Kohnen T, Koch DD. Optimizing intraocular lens power calculations in eyes with axial lengths above 25.0 mm. J Cataract Refract Surg. 2011;37:2018–2027
National Institute for Health and Care Excellence (UK). Cataracts in adults: management. London: National Institute for Health and Care Excellence (UK); 2017 Oct. (NICE Guideline, No. 77.) 7, Preoperative assessment and biometry. Available from: https://www.ncbi.nlm.nih.gov/books/NBK536589/
Ladi JS. Prevention and correction of residual refractive errors after cataract surgery. J Clin Ophthalmol Res 2017;5:45-50
Melles RB, Holladay JT, Chang WJ. Accuracy of Intraocular Lens Calculation Formulas. Ophthalmology. 2018;125(2):169-178. doi:10.1016/j.ophtha.2017.08.027
Patel RH, Karp CL, Yoo SH, Amescua G, Galor A. Cataract Surgery After Refractive Surgery. Int Ophthalmol Clin. 2016;56(2):169-180. doi:10.1097/IIO.0000000000000106
Kuthirummal N, Vanathi M, Mukhija R, et al. Evaluation of Barrett universal II formula for intraocular lens power calculation in Asian Indian population. Indian J Ophthalmol. 2020;68(1):59-64. doi:10.4103/ijo.IJO_600_19
Chen H, Chen X, Wang H, Fang Z, Yao K. Intraocular Lens power calculation after laser refractive surgery: A Meta-Analysis. Sci Rep. 2020;10(1):2645. Published 2020 Feb 14. doi:10.1038/s41598-020-59487-1